VarioSwitch
010
a/12V
010
a/24V
015
a/12V
015
a/24V
Dimensions
(
LxWxH)
[
mm]
150
x 120 x 210
150
x 120 x 210
170
x 130 x 240
170
x 130 x 240
Nominal voltage
12
V / AC
24
V / DC
12
V / AC
24
V / DC
Power consumption
[
W]
2
x 8
2
x 8
2
x 8
2
x 8
Flow ratemin.
[
l/min]
35.0
35.0
85.0
85.0
Flow ratemax.
[
l/min]
95.0
95.0
325.0
325.0
Pressure min.
[
bar]
0.1
0.1
0.2
0.2
Pressure max.
[
bar]
3.4
3.4
3.0
3.0
Protection class
IP 58
IP 58
IP 58
IP 58
Strainer
[
ø mm]
2
2
2
2
Material
Polyacetal / Stainless steel Polyacetal / Stainless steel Polyacetal / Stainless steel Polyacetal / Stainless steel
Weight
[
kg]
5.2
5.2
6.7
6.7
Cable length
[
m]
2.0
2.0
2.0
2.0
Order no.
50253
57472
50254
57435
Water flow and pressure requirements of the Vario-Switch with different nozzles
Model
Vario-Switch 010a/12V + Vario-Switch 010a/24V
Vario-Switch 015a/12V + Vario-Switch 015a/24V
Nozzle
Comet 10-12T
Comet 10-14T Schaumsprudler 35-10E
Comet 15-17T
Schaumsprudler 55-15E
Fountain height
DDB DWB DDB DWB
DDB DWB
DWB
DDB
DDB
DWB
[
m]
bar
l/min
bar
l/min
bar
l/min
bar
l/min
bar
l/min
0.50
0.21
27 0.25
31 0.42
38
0.16
100
0.50
158
1.00
0.35
37 0.46
40 0.72
49
0.22
123
0.92
209
1.50
0.60
46 0.66
48 0.98
57
0.32
137
1.42
255
2.00
0.72
50 0.86
55 1.22
63
0.42
154
1.92
291
2.50
0.86
55 1.06
61 1.52
70
0.52
168
2.48
322
3.00
1.02
60 1.32
67 1.80
76
0.62
181
2.80
343
3.50
1.22
65 1.55
73 2.10
81
0.72
192
4.00
1.38
70 1.82
79
0.82
202
4.50
1.64
75 1.96
82
0.92
214
5.00
1.82
80 2.18
87
1.02
218
5.50
2.10
85 3.00
96
1.12
230
Order no.
Comet 10-12 T
(
see page 28)
50968
Comet 10-14 T
(
see page 28)
50969
Comet 15-17 T
(
see page 28)
50970
Comet 10-14 T Silver
(
see page 26)
50723
Comet 15-17 T Silver
(
see page 26)
50724
Schaumsprudler 35-10 E
(
see page 44)
50984
Schaumsprudler 55-15 E
(
see page 44)
50987
Accessories
(
must be ordered separately)
17
OASE Fountain Technology / Lake Management – Catalogue
Nozzles
Controllable
In musical water organs or other spray fountain
installations with dynamic elements water becomes
lively with help from Vario switch systems.
This water switch is combined with a suitable nozzle
and switches between two outputs – similar to a 3/2-
way valve – almost without pressure loss and without
water hammer effects in the lines. Normally one of
those outputs is used as a pure bypass, however a
second nozzle can also be mounted.
The air supply for alternately switching atmospheric
pressure on and off is executed via the telescopic
tube using the so-called Coanda effect. Switchover
time is flow dependent and times of 0.1 s are certainly
achievable.