OASE | Catalogue 2014 - page 157

The fanless controller transmits DMX-RDM data
packets to the individual components (lights, pumps,
DMX-RDM controllable nozzles, motion etc.) which
enable them to act accordingly. In turn, they analyse
the received data and send back their status signals like
operating hours and temperature via the same cable.
These status signals enable remote diagnosis and
remote maintenance of the connected components.
The digital inputs can be linked to water level sensors
or external push buttons. That enables to control shows
and faders from outside.
Furthermore, as a special feature, the OASE Wind
Anemometer drives the internal wind-fader directly to
control fountain heights according to the wind speed.
All digital outputs can be used to switch relays and fre-
quency converters directly.
Any number of shows or sequences for a project can be
saved on the micro SD card (4 GB included).
Hardware
512 channel RDM/DMX output
1024 channel RDM/DMX output
Easy to use front panel setup
Interface 1024 channel
8 digital output
8 digital input
DIN rail housing
Audio output
Stand alone
Stand alone capable
Stand alone micro SD card 4GB
Show upload via micro SD card
Stand alone calendar
Connectivity
Ethernet RJ45 10/100 Mbit
Software
Fixture library
Patching
Operating & monitoring (Live page)
RDMmonitoring
Logbook files
Scenes
Sequences
Scheduler
DMX channel preview
Effects: SIN, COS, RECT, SAW UP/-DOWN
Matrix programming
Time schedule with internal clock
Media support audio
WECS II 512/DMX/02 WECS II 1024/DMX/02
WE C S I I 5 1 2 / 1 0 2 4
o v e r v i e w
A
Any number of shows or sequences for a project can be saved
on the micro SD card (4GB included).
B
RJ-45 Ethernet
C
Audio 3,5 mm stereo jack, galvanically isolated
D
Connection of voltage supply +24V DC for digital outputs (-/+)
E
8x digital output 1A/output, galvanically isolated
F
4x connection to power supply (++/--) 15-24 V DC /8W
G
2x DMX-RDM outputs, galvanically isolated
H
2x grounding for digital inputs
I
8x digital inputs, galvanically isolated
A B
C D
E
I
H G
F
157
OASE Fountain Technology / Lake Management – Catalogue